A complete system
Tested & Passed all criteria for AS 5113 – External wall and Fire Spread requirements
Manufactured in Australia
New level of fire protection
New level of thermal properties
Prefab sections delivered direct to site
Slot into place and secure
Build, clad and insulate all in one
MetecnoKasset is a durable, insulated wall and ceiling panel with a modified PIR (Polyisocyanurate) fire-retardant core and high performing thermal properties. MetecnoKasset is available in a range of COLORBOND® colours, a palette of choice to create an inspiring interior and exterior finish.
Module Properties | |
---|---|
Module Thickness | 115 mm |
Module Height | Made to measure up to 3800mm in height |
Module Width | Made to measure incorporating 1100mm wide panels |
Mass | 22.1 kg/m2 |
Acoustic Properties | Rw 25-37* |
Thermal Performance | ‘R’ Value: 4.91 W/m2K; ‘U’ Value: 0.20 m2K/W |
Module composition | Modified FM approved PIR (Fire –retardant Polyisocyanurate) panel with prefinished profiled steel skins and internal skin lined with 6mm fibre cement. |
Frame Material | Anodized or Powder coated extruded Aluminium with extruded weather seals |
Colours | Choice of any Colorbond® standard, metallic or custom colour for external skin, frame and trims. |
Finishes | Panel surface can be supplied in Plain, Fineline, Satinline or Ribbed profiles. |
* depending on system
Tests & Engineering | |
---|---|
Façade Fire Evaluation testing to NATA accreditation requirements by Exova Warringtonfire Aus. | Testing to AS 5113 according to their tendency to limit the spread of fire across their surface and between neighbouring buildings and integrates international standard test methods where practicable. |
Building performance testing in Australia to NATA accreditation requirements by Ian Bennie & Associates | Structural SLS, Air Infiltration, Water Penetration and Structural ULS test procedures and performance requirements in accordance with standard AS/NZS 4284:2008, Testing of Building Facades. Optional tests: including BMU restraint, seismic loading and seal degradation. |
Engineering certification to the provisions of the section B1 of the Building Code of Australia and the Australian Standards by Inhabit Australasia | AS/NZS 1170.0:2002- Structural design actions - Part 0: General Principles AS/NZS 1170.1:2002, Structural design actions - Part 1: Permanent, imposed & other actions AS/NZS 1170.2:2002, Structural design actions - Part 2: Wind actions AS/NZS 1664.1:1997, Aluminium Structures AS4100:1998, Steel Structures |
Codemark Certification | Coming Soon |